Low-voltage substation device for high-voltage automatic circuit breakers (instantaneous excitation method)

This is a remote-controlled substation device used for the time-limited forwarding method that enables the separation and reduction of power outage sections during distribution line accidents, as well as the transmission of power to healthy outage sections.

In general, high-voltage distribution lines are equipped with multiple high-voltage automatic sectionalizers (hereinafter referred to as sectionalizers) along the route, and a time-delayed transfer method is adopted to enable the separation and reduction of outage sections during distribution line accidents and to allow power transmission to healthy outage sections. This device is a remote-controlled substation device used in combination with these sectionalizers.

  • Monitoring and Control Equipment
  • others
  • Security cameras and surveillance systems

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Substation device with built-in ground fault direction detector for manual switchgear (MSD substation device)

Since the direction of the ground fault accident can be confirmed, it is very convenient for accident investigation! Accident information will be transmitted to the business office via remote monitoring.

■□■Features■□■ ■This device is used in combination with a manual switch that has a built-in ground fault direction detector. ■In the event of a ground fault accident occurring on the distribution line, this device determines which direction (power side or load side) the ground fault is occurring from the installation point of the device and transmits that information to the business office via remote monitoring. ■By installing this device, it becomes possible to grasp the ground fault direction based on the installation point, which reduces the scope of accident investigation, thereby facilitating labor-saving in accident recovery and simultaneously shortening power outage time. ■The device itself is also equipped with a ground fault direction indicator (MagSign), allowing for visibility of the ground fault direction from the ground on-site. ■Since the device is equipped with a backup battery, it can transmit accident information to the business office even during a power outage caused by an accident.

  • Monitoring and Control Equipment
  • others
  • Security cameras and surveillance systems

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low Voltage Substation Device for Circuit Breaker Protection on Poles (TCR)

Low Voltage Substation Device for Circuit Breaker Protection on Poles (TCR)

In cases where short-circuit accidents occur near the ends of long distribution lines or after insulation transformers, and cannot be protected by the protective relays of distribution substations, this device is installed and used along the distribution line. This device is used in combination with high-voltage equipment (recloser high-voltage equipment). Additionally, by installing it near the boundary between urban and suburban areas, it also has the effect of preventing the impact of accidents occurring in the suburbs from spreading to urban areas.

  • Monitoring and Control Equipment
  • others
  • Security cameras and surveillance systems

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Substation device with ground fault reclosing function for high-voltage automatic circuit breakers (simple REC)

It becomes possible to isolate the accident point and reduce the power outage range without operating the feeder CB.

By using it in combination with high-voltage automatic circuit breakers and high-voltage ground fault direction indicators, it is possible to separate the fault point and reduce the scope of power outages on distribution lines where intermittent ground fault incidents and instantaneous ground fault incidents occur repeatedly without operating the feeder circuit breaker. Since it can be used with high-voltage automatic sectionalizers, there is no need for special pole-mounted reclosing protection devices (recloser high-voltage devices). Additionally, due to its small and lightweight design, it is easy to relocate and install along with portable high-voltage ground fault indicators.

  • Monitoring and Control Equipment
  • others
  • Security cameras and surveillance systems

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration